Skip to content

Samlex 2200 Watts 12V Pure Sine Inverter/Charger

by Samlex
SKU EVO-2212
Original price $1,790.00 - Original price $1,790.00
Original price
$1,790.00
$1,790.00 - $1,790.00
Current price $1,790.00
Availability:
Low stock

Get it between -

Profile Pic

Have a question? Talk to one of our trusted experts today!

Instant Live Chat: Chat IconChat Now

Call or Text us: Phone Icon 415-481-4075

Price Match Policy

Price Match

Here at OffGrid Living Solutions, we want to offer you the best prices online.

If you happen to find a lower price for the same product, we will guarantee to match their price or beat their price. Note, this does not apply to all products in the store. Please reach out to us via email or chat if you want a price match or price beat.

For the policy to apply, please send us a screenshot, link, or any other evidence of the product being priced lower than ours before making the purchase.

Refer to our Price Match Policy Rules.

Refunds & Returns Policy

At OffGrid Living Solutions, we are proud to have the best refund and return policies in the industry. If you’re not satisfied with your purchase for any reason, you may return it to us within 30 days for a refund.

If you have a problem with our order (there are missing components, damages, or the product is not functioning), please reach out to us as quickly as possible. Some of the problems can be resolved by going through the product manual or the product FAQs.

Refer to our Refunds & Return Policy for more details.

Shipping & Delivery

Order Processing

Once we receive your order, we will send you a confirmation email. Then we will process the order by confirming that the product is in stock and ready for shipment. If any of the items in your order are back-ordered, we will reach to you via email or phone and you may choose to either wait or receive a 100% refund.

Please allow 1-3 days for processing your order.

Shipping

We ship to the lower 48 continental United States only at this time.

Shipping times and shipping method will depend on the specific product and brand you purchase. If you have any shipping question, feel free to ask on the chat or email us at info@offgridlivingsolutions.com.

We will send tracking information by email the same day the shipping tracking number is created/available.

Before you sign the shipping bill, please THOROUGHLY INSPECT YOUR ITEM. Signing for the receipt of a damaged product removes the liability of the shipping company and OffGrid Living Solutions. Once you accept your shipment as non-damage, your item is your property.

Delivery time

Shipping Timeline listed above is an estimate. Please call or message the web chat for precise ETAs.

Samlex 2200 Watts 12V Pure Sine Inverter/Charger

Description

Pure sine wave inverter, adaptive battery charger, transfer relay – All in ONE unit. Samlex Evolution Series inverter/chargers provide reliable AC power wherever it’s needed. For use with boats, RVs, cabins and specialty vehicles, as well as alternative energy, back-up and emergency power applications.

Using state-of-the-art technology, the Samlex EVO inverter/charger operates at 165 million instructions per second with lightning fast load & response times, has 9 points of physical protection monitoring (being scanned up to 10,000 times per second) to detect fault conditions & protect itself in a vast range of adverse environments.

The EVO-2212 is a 2200 Watt Pure Sine inverter, 12 VDC input, 120 VAC output, 50/60 Hz. It intelligently integrates a 100 Amp 4 stage Battery Charger and a 40 Amp Transfer Relay into an advanced and affordable off-grid power solution.

Also available in 24V input: EVO-2224 or 230 VAC output: EVO-2212E

EVO-RC remote control sold separately

Features

AC Inputs

  • Two separate AC inputs – one for grid (priority #1), one for generator (priority #2), connect simultaneously, no need to reconfigure when different power sources are available.
  • Each AC input is programmable for voltage and frequency. User determines what the min and max thresholds are to switch from Grid or Generator to Inverter.
  • Generator start can be initiated by “Status Relay” contact, can be programmed to activate when grid is lost.

Solar Input

  • Connect a solar charge controller directly to the EVOTM through the Battery Charger external DC Input, seamlessly integrates solar charging into the EVO’s power system.
  • ONLINE Mode can be used to prioritize Batteries/Inverter over the grid, ideal for those wishing to operate primarily on solar power (when the grid is available, but might be costly).

Battery Charger

  • 3 or 4 stage charging with Equalization (must be manually initiated).
  • Adaptive algorithm is used during Bulk to assess the condition of the battery. Subsequent stages are then based on the condition of the battery rather than pre-set time periods for Absorption and Float. Prevents unnecessary charging, extends the life of batteries.
  • Programmable – set battery voltage thresholds to initiate charging.

Transfer Switch

  • Zero transfer time when switching from Inverter to Grid. When grid comes on, the inverter synchronizes with the wave form and then transfers instantly at zero crossing.
  • <16ms transfer when going from Grid to Inverter. When grid is lost, the transfer relay switches to inverter at the correct place in the wave form, the transfer takes less than 16ms.

Surge Capacity (Power Boost)

  • The EVOTM has 3X surge power
  • Additionally, the EVOTM has large power overload allowances available for long periods of time. Increased inverter capacity means you can size your inverter smaller to handle heavy surge loads, reducing costs.

State-of-the-Art Technology

  • The EVOTM operates at 165 million instructions per second producing lightning fast load and response times
  • The EVOTM is practically indestructible. It has “Bullet-Proof Intelligence” in the form of 9 physical points of protection monitoring being scanned up to 10,000 times per second for adverse conditions. The EVOTM will detect fault conditions and initiate a healthy shutdown before any product damage can be done.
  • The EVO-RC remote control (sold separately) can be used to capture detailed EVOTM performance data. Records all detected faults and the conditions leading up to them. Data is stored on a removable 32GB SD Card (in the remote). Use data to analyze trends for more efficient use of system resources
  • The EVOTM uses five temperature sensors placed throughout the unit to determine operation of 2 speed controlled cooling fans. Reduces unnecessary fan noise and energy consumption by only running when and where the fans are needed.

Product Specifications

Samlex 2200 Watts 12V Pure Sine Inverter/Charger Product Specifications

Feature Specification
Input 12 VDC
Output 120 VAC
Watts 2200 Watts
Surge 6600 Watts
Outlets Hardwired
Fuse External
Remote Control EVO-RC (Optional)
Weight 59 lbs / 27 kg
Dimensions 12.79 x 16.77 x 8.15 in / 325 x 426 x 207 mm
Safety ETL safety listed to UL standards: 1741, 458, and CSA C22.2 No. 107.1-01. EMI/EMC compliant with FCC Part 15(B), Class A. RoHS Compliant.

Product Manual

Samlex 2200 Watts 12V Pure Sine Inverter/Charger Product Manual

Samlex Product Manual

Samlex Specifications

Samlex Quick Start Guide

Product Warranty

3 Years Limited Warranty

Product FAQs

What is a Pure Sine Wave Inverter?
The output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains / utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.
What are the advantages of Pure Sine Wave inverters?
  • The output wave-form is a sine-wave with very low harmonic distortion and clean power like utility supplied electricity
  • Inductive loads like microwaves and motors run faster, quieter and cooler
  • Reduces audible and electrical noise in fans, fluorescent lights, audio amplifiers, TV, fax and answering machines
  • Prevents crashes in computers, weird print outs and glitches in monitors
What is a Modified Sine Wave Inverter?

In a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.

What are the advantages of Pure Sine Wave inverters?
  • The output wave-form is a sine-wave with very low harmonic distortion and clean power like utility supplied electricity
  • Inductive loads like microwaves and motors run faster, quieter and cooler
  • Reduces audible and electrical noise in fans, fluorescent lights, audio amplifiers, TV, fax and answering machines
  • Prevents crashes in computers, weird print outs and glitches in monitors
Which devices will not function properly from a Modified Sine Wave Inverter?

Any device that uses a control circuitry that senses the phase (for voltage / speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors / microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors / power factor improvement capacitors.

Some examples of devices that may not work properly with modified sine wave and may also get damaged are given below

  • Laser printers, photocopiers, magneto-optical hard drives
  • The built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly
  • Output voltage control devices like dimmers, ceiling fan / motor speed control may not work properly (dimming / speed control may not function)
  • Sewing machines with speed / microprocessor control
  • Transformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools. These may get damaged. Please check with the manufacturer of these types of devices for suitability
  • Devices that use radio frequency signals carried by the AC distribution wiring
  • Some new furnaces with microprocessor control / Oil burner primary controls
  • High intensity discharge (HID) lamps like Metal Halide lamps. These may get damaged. Please check with the manufacturer of these types of devices for suitability
  • Some fluorescent lamps / light fixtures that have power factor correction capacitors. The inverter may shut down indicating overload
What is a DC-AC inverter?

When you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.

Batteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.

An inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.

What are the criteria for selecting the right inverter for a particular application?

To choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.

When sizing an inverter, you need to take into consideration both the running power  (continuous) and the additional starting surge power requirements of the AC side loads.

Some loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:

  • Running Power, Watts – Wr
  • Additional Starting Power or Additional Continuous Power, Watts – Wa
  • Total Starting Surge Power, Watts = Running Power (Wr) + Additional Starting Power / Additional Continuous Power (Wa)

The specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for > 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power. Only the Continuous Power rating of the inverter should be considered in such cases.

Electric motor driven compressor/pump based loads like refrigerators/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power Wa should be taken as 4 times the Running Power Wr.

Switched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power Wa should be taken as 2 times the Running Power Wr. Consumer electronics like computers, TV, VCR, audio/ video devices, etc. use this type of power supply. (Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9).

Motors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power Wa should be taken as 2 times the Running Power Wr. This starting power normally lasts from 2 to 5 seconds.

The Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power Wa should be taken as 1 time the Running Power Wr. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. (If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).

The following symbols and equations are used in the sizing of an inverter example below:

  • Total Running Power of the items selected, Watts – Wrt
  • Highest Additional Starting Power out of the items selected, Watts – Wah
  • *Highest power for sizing purpose, Watts – Wrt + Wah

* It is assumed that only one out of the selected items starts at one time

Since the AC loads rarely start at the same time, the load with the highest Additional Starting Power Wah has been factored in.

Example:

Device / Appliance

Running Power, Wr, Watts

Additional
Starting Power or Additional Continuous Power *, Wa, Watts

Quantity

Extended
Running Power, Wt, Watts

Refrigerator – Electric Compressor based

200

800

1

200

Color TV

225

450

1

225

Laptop Adapter

120

240

1

120

Incandescent Lamps

60

0

6

360

 

* Additional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.

Total Extended Running Power, Wrt = 200 + 225 + 120 + 360 = 905 Watts

Highest Additional Starting Power, Wah = 800 Watts

Highest Power for sizing the inverter = Total Running Power, Wrt(905 W) + Highest Additional Starting Power, Wah (800 W) = 1705 Watts

What are the electrical standards pertaining to DC-AC inverters?

The DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.

The inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.

What are "continuous" and "surge" power capacity ratings for DC-AC inverters?

How much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.

How do "surge power" electrical loads affect DC-AC inverter operation?

If an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.

Any weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.

How should I size my DC-AC inverter for loads that require starting surge?

Observe the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device/appliance by the Surge Factor)

NOTE: The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.

Device / Appliance

Surge Factor
(No. of times the running power rating of the device/appliance)

 

Refrigerator / Freezer

5

Air Compressors

4

Dishwasher

3

Sump pump

3

Furnace fans

3

Industrial motors

3

Circular saw

3

Bench Grinder

3

Portable diesel / kerosene fuel heater

2

How should I size my DC-AC inverter to operate a microwave?

The power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.

How should I size my DC-AC inverter to power a water supply pump?

A water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.

In North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1/2 HP.

What is "idle power" in a DC-AC inverter?

Idle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.

What are Phantom and idling loads?

Most of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.

A similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.

Can a standard DC-AC inverter be connected in parallel with another AC source/ DC-AC inverter / electrical utility?

The AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel / load center which is also fed from the utility power /generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility / generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.

If an electrical breaker panel / load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility / generator / inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel / load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home/RV.

How can DC-AC inverters be connected to multi-wire branch circuits?

Do not directly connect the hot side of the inverter to the two hot legs of the 120 / 240 VAC electrical breaker panel / load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading/overheating of the neutral conductor and is a risk of fire.

A split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 / 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel/ load centre.

How should I size my DC-AC inverter to supply computer or printer loads?

Computers and Printers generally come with in-built switch-mode power supplies (see application notes and FAQs on switch mode power supplies (SMPS)) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.

What is the difference between a 12V, 24V and 48V inverter?

A 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)