Victron Energy MultiPlus 12V/1200W/50-16 120V VE.Bus Inverter Charger
Description
The new style MultiPlus is set to replace the earlier MultiPlus Compact range. It is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology and a high-speed AC transfer switch in a single compact enclosure.
Models:
500VA, 800VA, 1200VA, 1600VA
Uninterrupted AC power (UPS function)
In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.
Remote Monitoring and Control
When coupled with a GX device (e.g. Cerbo GX) you can monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, from adjusting your Multi to auto starting a backupgenerator and more…"
Product Specifications
Victron Energy MultiPlus 12V/1200W/50-16 120V VE.Bus Inverter Charger Product Specifications
Specifications:
- PowerControl: Yes
- PowerAssist: Yes
- Transfer Switch (A): 16
Inverter Specifications:
- Input Voltage Range (V DC): 9,5 – 17 V, 19 – 33 V, 38– 66 V
- Output voltage: 230 VAC, ± 2% / Frequency 50 Hz ± 0,1%
- Continuous Output Power at 25°C (VA): 1200
- Continuous Output Power at 25°C (W): 1000
- Continuous Output Power at 40°C (W): 900
- Continuous Output Power at 65°C (W): 600
- Peak Power (W): 2400
- Maximum Efficiency (%): 93 / 94 / 95%
- Zero Load Power (W): 10 / 9 / 10 W
- Zero Load Power in Search Mode (W): 3 / 3 / 3 W
Charger Specifications:
- AC Input: Input voltage range: 187-265 VAC / Input frequency: 45 – 65 Hz
- Charge Voltage Absorption (V DC): 14,4 / 28,8 / 57,6
- Charge Voltage Float (V DC): 13,8 / 27,6
- Storage Mode (V DC): 13,8 / 27,6 / 55,2
- Charge Current House Battery (A): 50 / 25 / 13 A
- Charge Current Starter Battery (A): 1A (12 V and 24 V models only)
- Battery Temperature Sensor: Yes
General Specifications:
- Programmable Relay: Yes (1x)
- Protection: a - g
- VE.Bus Communication Port: For parallel and three-phase operation, remote monitoring and system integration (RJ45-splitter ASS030065510 needed for 500 / 800 / 1200 VA models)
- Remote On-Off: On/off/charger only
- DIP Switches: Yes
- Internal DC Fuse: 200 / 100 / 50 A
- Operating Temperature Range: -40 - +65°C / -40 to 150°F (fan-assisted cooling), Humidity (non-condensing) max 95%
Enclosure Specifications:
- Common Characteristics: Material & Color: aluminum (blue RAL 5012) / Protection category: IP 21
- Battery-Connection: 35 / 25 / 10 mm²
- 230 V AC-Connection: G-ST18i connector
- Weight: 8.2 kg
- Dimensions (H x W x D): 406 x 250 x 100 mm / 15.98 x 9.84 x 3.94 in.
Standards:
- Safety: EN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1
- Emission, Immunity: EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
- Automotive Directive: ECE R10-5
- Can be adjusted to 60Hz and 240V
- Protection: Output short circuit, Overload, Battery voltage too high, Battery voltage too low, Temperature too high, 230VAC on inverter output, Input voltage ripple too high
- Non-linear load, crest factor 3:1
- Up to 25°C ambient
- A programmable relay that can be set for General alarm, DC under voltage or generator start/stop signal function, AC rating: 230V/4A, DC rating: 4A up to 35VDC, 1A up to 60VDC
- Remote/battery charge voltage/inverter frequency/search mode
- Battery charge voltage/search mode
Product Manuals
Victron Energy MultiPlus 12V/1200W/50-16 120V VE.Bus Inverter Charger Product Manuals
MutiPlus 12V 500-1200VA 120VAC
Energy Storage System
Automatic Generator start-stop
Solar & Wind Priority
VictronConnect configuration guide for VE.Bus products
Product Warranty
Victron Energy Product Warranty
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.
For a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.
During the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
• Reverse of battery polarity.
• Inadequate connection.
• Mechanical shock or deformation.
• Contact with liquid or oxidation by condensation.
• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...).
• Breakage or damage due to lightning.
• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.
• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and/or the input/output X and Y capacitors determine the warranty.
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.
Repair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.
Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.
All remedies and the measure for damages are limited to the above.
Victron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.
Product FAQs